 275 Specifications
DC Voltage Max Range:600V
Max Resolution:0.1mV
Basic Accuracy: 0.5%
AC Voltage Max Range:600V
Max Resolution:0.1mV
Basic Accuracy: 0.5%
DC Amps Max Range:400A
Max Resolution:0.1A
Basic Accuracy: 0.8%
DC Microamps Max Range:1100uA
Max Resolution:0.01uA
Basic Accuracy: 0.8%
AC Amps Max Range:400A
Max Resolution:0.1A
Basic Accuracy: 3%
Resistance Max Range:110MΩ
Max Resolution:0.1Ω
Basic Accuracy: 1%
Frequency Max Range:110MHz
Max Resolution:0.1Hz
Basic Accuracy: 1%
Capacitance Max Range:110mF
Max Resolution:0.001nF
Basic Accuracy: 3%
Temperature Max Range:1000°F
Max Resolution:1°F
Basic Accuracy: 1%
Non-Contact Voltage (NCV) 24VAC and above
Continuity Buzzer <35Ω
Diode Test 1.5mA Max
True RMS Response Yes
Peak Hold Yes
Relative Mode Yes
Min/Max Record Yes
Data Hold Yes
% Total Harmonic Distortion No
Range Selection Auto / Manual
Display Type 11000 count LCD
Operating Temperature 32°F to 104°F
Relative Humidity 80% non-condensing
Storage Temperature 14°F to 122°F
Battery Type 9V (MN1604)
Battery Life 80hrs typical
Auto Off / Sleep Mode Yes
Dimensions (H x L x W) 1.3” x 10” x 2.5”
Weight 0.8lb
Agency Approval CE IEC 61010: CAT III, 600V
cULus 61010

 275 Applications
Measure flame safety control current
Test start and run capacitors & motors
Measure motor run current and capture peak motor start up and amperage
Measure heat anticipator current
Determine thermocouple voltage
Test line and control voltage
Measure heating element resistance
Measure air temperature in ducts
Test for the presense of voltage in circuits without contacting the circuit
Measure temperature differential using relative mode

 CLAMP-On FAQs

1. How does the non-contact voltage feature of the TPI 270 and 275 benefit me?

The non-contact feature of the TPI 270 and 275 allows you to detect live circuits without using the test leads, which enables faster checks for the presence of voltage.

2. Which of the TPI clamp-on meters will measure temperature?

The 270 and 275 have this feature built in and the 255, 265, and 291 can measure temperature by using the optional A301 or a A312 K-type thermocouple adapters.

3. Which TPI clamp-ons can measure DC microamps?

The TPI 270 and 275 has the capability to measure DC microamps by using the test leads. This is very useful for making flame safety control current measurements. The 265 can measure DC microamps with the optional A213 adapter.

4. Does a clamp-on meter measure anything besides amps?

All TPI clamp-on meters measure AC/DC volts and resistance. Models are available with temperature, frequency, capacitance, and non-contact voltage detection capability as well as many other features. Various adapters including temperature (A301 or A312), carbon monoxide (A771), and pressure (A620/630) are available. Contact TPI for additional information.

5. Is it possible to measure AC amps on a device that uses a power cord?

Yes, to accomplish this you can use the TPI line splitter (A202). AC amps must be measured by isolating a single wire and the A202 line splitter does this without damaging the power cord.

Instruction Manual

Currently there are no reviews for this product. Share your opinion with others, be the first to write a review.

Add Your Review


Your Name:
Email Address:
Review:
Note: HTML is not translated! Your email address will not be shared with anyone.
Your Rating: 5